Cookies help us deliver our services. By using our services, you agree to our use of cookies.
<span style="font-size: 12pt;">Function</span> <br /><span style="font-size: 12pt;">‧TX FA Coupling</span> <br /><span style="font-size: 12pt;">‧TX FA Align with PIC</span> <br /><span style="font-size: 12pt;">‧Fixed the FA after Coupling by UV Glue (Include Glue Fixed and UV Curing)</span> <br> <br> <br /><span style="font-size: 12pt;">Key Point</span> <br /><span style="font-size: 12pt;">‧RSSI ADC</span> <br /><span style="font-size: 12pt;">‧High-Precision Stage to Align X/Y/Z Plane </span> <br /><span style="font-size: 12pt;">‧Online Monitoring and Data Uploading to Database</span>">
Update:2025.04.10
Station details
Station | Function | Key Point |
SiPh Chip Tester | ‧SiPh Chip Design Verification ‧Academic and Laboratory Research ‧Mass Production Testing and Quality Control | ‧High-Reliability Nanometer-Scale Alignment Precision ‧Semi-Automated Optical Coupling and Alignment Testing ‧Multiple measurement capabilities for O-O, O-E, E-O, and E-E device configuration |
Major equipment
Equipment | Key Parameter |
Fine Positioning | ‧X/Y/Z Resolution: 2nm ‧X/Y/Z Repeatability: 5nm |
Specification Sheet
Type | Item | Parameter |
Equipment Dimensions & Power | Power Input | 220V 50/60Hz |
Pneumatic System | Compressed air flow >500PM; System supply pressure 0.6MPa-0.7MPa | |
Vacuum System | Vacuum gauge reading -53 ~ -100kPa | |
Environmental Conditions | Temperature: 15-35°C; Humidity: standard 60% at 22°C; Cleanliness level: 10k Class | |
Machine Dimensions | 1660mm×1610mm×1550mm | |
Equipment Weight | 1500kg | |
Safety Protection | Product Safety Protection | Contact grounding treatment |
ESD Protection | Ion fan for electrostatic removal | |
Software Protection | Mistake proofing | |
Equipment Protection | Collision prevention, axis stroke limit, distance sensor | |
Operator Safety Protection | Protective goggles | |
Motion and Positioning Systems (coarse positioning) | Operating module | Dual 6 axis module |
Workpiece Clamping | Electric clamp, vacuum suction fixation | |
Repeatability XYZ Drive Mechanism | ±0.05μm Step motor with ball screw | |
XYZ motion stroke | ±15mm | |
Maximum movement speed | 15mm/s | |
Motion and Positioning Systems (fine positioning) | Control axis | XYZ axis |
Resolution | 2nm | |
Bi-directional repeatability (10% movement range) | 5nm | |
Alignment System | Scan time - spiral area 10 µm | <0.5s |
Scan time - gradient ±5 µm | <0.3s | |
Repeatability | 0.02dB | |
Z-axis Sensing System | Sensing range | 2.4mm |
Resolution | 24nm | |
Microscope Movement System | Travel Distance | XY axis 50mm; Z axis 127mm |
Resolution | 1μm | |
Repeatability | ±3μm | |
Probe Station System (XYZ platform) | Travel Distance | X axis 350mm; Y axis 365mm; Z axis 20mm |
Resolution | 0.1μm | |
Repeatability | ±1μm | |
Accuracy | ±2μm | |
Probe Station System (Theta platform) | Travel Distance | ±10° |
Resolution | 0.0001° | |
Repeatability | 0.0005° | |
Accuracy | 0.001° | |
Wafer chuck | Diameter | 310mm |
Surface flatness | ±10μm | |
Test object size capability | single DUT ,2 ,4, 6 ,8 ,12 inch | |
Temperature control system | Temperature controllable range | Recommended operating range -40°C to 100°C, Extended Maximum Temperature Up to 300°C |
Heating and cooling rate | Heating: -40°C to 25°C < 30 min; 25°C to 300°C < 50 min Cooling: 300°C to 25°C < 60min; 25°C to -40°C <60 min |